The ship arrives at night. A 2011-built bulk carrier of about 35,000 tonnes deadweight, holds loaded with 33,000 tonnes of raw cane sugar, four 30.5-tonne cranes on deck and three generators in the engine room to feed them. By 23:00 she is fast alongside at Oran. At 01:25, discharge begins — and from the very first hour, something is wrong. Only two of the four cranes are working. The ship’s own Statement of Facts gives the reason: the other two cannot operate for lack of power supply.

The crew say the cause lies below decks. Generator No. 2, they report, stopped at midnight. By the time a surveyor steps aboard the next day, the crisis is reportedly over, the repair is reportedly done, and the cargo receivers have already put their objections in writing. Everything that matters has already happened. What remains is the hardest kind of evidence to weigh: an account.

01

The Context

The receivers’ Letter of Protest is precise. It records that the vessel could not put more than two cranes to work at once, that the cranes stopped repeatedly and cycled slowly, and that the contractual discharge rate was out of reach as a result. It reserves the right to claim for idle stevedores, trucks left waiting, additional handling costs and demurrage. No figure is attached — for now, only a reservation.

The ship’s explanation is technical. The high-pressure fuel pumps and injectors of generator No. 2 failed; the machine stopped after being connected, with a frequency alarm on the screen; and without it, the crew say, there was not enough power to run more than two cranes. A marine surveyor is called in, with a mandate that is deliberately narrow: test that account against the evidence. Not to rule on liability. Not to calculate delay. Not to price the loss. One question, and a hard one — how do you verify a breakdown you did not witness?

02

Arriving After the Event

The surveyor boards after the fact, which is where forensic work usually begins. There is no time-stamped alarm record to consult, no repair report, no test report. What exists is four things: a page of the engine logbook, a Statement of Facts signed by the Master, a questionnaire completed by the Chief Engineer — and the ship herself, with her switchboard, her generators and her workshop bench. The first three come from the vessel. Only the last can be observed first-hand.

So the method starts with a discipline of separation. The logbook is transcribed, its uncertain readings marked, its internal consistency checked. Every event from every source is placed on one timeline. Then each claim is graded into one of four boxes: consistent, compatible, reported but not verified, or hypothesis. No claim is allowed to sit in a box it has not earned. What the surveyor observed directly, what the crew reported and what nobody can confirm are kept strictly apart.

03

A Story That Fits

Laid side by side, the vessel’s documents tell a clean story.

At midnight, according to the Chief Engineer, generator No. 2 is connected, then stops. The alarm reads “Power indicator frequency.” Repairs begin at once. At 01:25 discharge starts with cranes No. 2 and 3; cranes No. 1 and 4 are out of service. Between 07:20 and 11:00 the ship works with two cranes — three hours and forty minutes. The repair is declared complete at 10:30, a test runs until 11:00, and at 11:00 the agent is told that all cranes are operational.

The Chief Engineer’s account and the Master’s timing statement agree almost to the minute — and that is exactly the moment for caution. Two accounts that agree are not two independent confirmations when both come from the same ship. The report grades them with care: compatible, not verified.

Even the stoppages are contested. The Master’s statement attributes the early hours of suspension to the port; the receivers’ protest describes crane interruptions and slow cycles. No joint operating record reconciles the two versions, and the two hours between 11:00 and 13:00 carry no operational entry at all.

04

Three Witnesses, None Decisive

With the vessel’s story on the table, the surveyor looks for anything that can be tested against it. Three witnesses are called. None settles the case. Each says something precise.

The first is the engine logbook — and it says nothing. Page 69 covers the whole night. It records no generator stop, no alarm, no restriction on the cranes; the remarks box is empty. A hasty reading would take that silence as a contradiction of the crew’s account. The surveyor refuses, because the logbook is unreliable on that very night. It shows the main engine “on preheat” from 20:00, while the Statement of Facts has the pilot on board at 21:50 and the ship still manoeuvring until 23:00. Generator No. 2 does not appear at all before the 08:00–12:00 watch. Several values are identical from one watch to the next, as if copied. Generators No. 2 and No. 3 both show an exhaust temperature of 449 °C, while generator No. 1 shows 258 °C at the same recorded load. A logbook that cannot be trusted on the main engine cannot be asked to testify about a generator. Its silence carries no weight in either direction.

The second is a set of parts on a workbench. On the following day, the Chief Engineer lays out what he says was removed: two fuel injection pump elements with their plungers, and a separate pump housing, dark with oily residue. The surveyor examines and photographs every piece. Nothing is measured; nothing is bench-tested. What the examination establishes is modest and exact: these components are consistent in appearance with a fuel injection pump assembly. What it cannot establish is what was wrong with them, when, or what role they played in the stop at midnight. The mechanism itself is technically sound. A worn pump element or a poorly spraying injector can starve a cylinder, unbalance combustion and, as electrical load rises, make an engine hunt in speed — which is precisely what a frequency alarm would describe. Plausible. But a plausible mechanism is not a diagnosis.

The third is arithmetic. Back in the engine room, the surveyor reads the switchboard while all four cranes discharge together on three generators in parallel. Each generator carries between 150 and 200 kW. Total: 450 to 600 kW, the ship’s base load included. Two generators rated at 465 kW each can deliver 930 kW. The ship is using 48 to 65 per cent of that. On this evidence, two healthy generators could have carried four cranes at average load — which seems, at first, to cut against the crew’s explanation.

It doesn’t settle it. An average is not a peak. Hydraulic pump motors start, cranes hoist and slew in the same instant, and load steps arrive in fractions of a second. If each of the four cranes drew more than roughly 100 to 150 kW at the same moment, two generators would be saturated. The reading was short, and the true peak draw of these cranes is unknown. The restriction itself may have been a precaution to keep reserve in hand, an instruction, or a power-management interlock; none of these has been verified. And the measurement was taken later, with three generators running, not two. It is compatible with the vessel’s account. It does not demonstrate it.

THE EVIDENTIAL CHAIN: The logbook was silent and unreliable. The parts were real but mute. The arithmetic was compatible but incomplete. Three witnesses, none decisive — and an honest report says exactly that.

05

What Would Close the Case

A forensic report is not finished when it stops writing. It is finished when it says what would finish it. Five records, named one by one:

Time-stamped alarm records for generator No. 2? They would fix the exact time and nature of the stop.
The repair report, the list of replaced parts and the test report? They would show what was actually defective, what was done, and when the work was completed.
The written crane operating instructions and the power-management settings? They would reveal whether the two-crane limit was a physical impossibility, an automatic interlock or a prudent decision.
The maintenance history of generator No. 2? It alone could test the idea of wear at the end of a docking cycle — today, nothing more than a hypothesis.
Load trends for generators No. 1 and 3 between 01:25 and 10:30? They would show what the two remaining machines were really carrying, and how close to their limits.

06

The Conclusion

So what can the report say? That the vessel’s account is coherent and internally compatible. That a fuel injection defect is a plausible cause of the reported unavailability of generator No. 2. That losing a generator could well have prompted a restriction on the cranes. And that the later load readings leave room for both explanations — a real shortage of power, or a precaution, an instruction, an interlock.

What it cannot say is just as clear. That the generator stopped at midnight: reported, not verified. That the defect lay in the pumps and injectors: presented, not demonstrated. That two cranes were all the ship could safely run: compatible, not proven. And on whether cargo time was lost, what that time cost and who should bear it, the report says nothing — by design. Liability was never the question.

A bolder report would have been easier to write — and easier to dismantle at the first cross-examination. This one commits to nothing it cannot support, names the records that could change that, and reserves the right to amend its findings if they ever appear.

All case studies

An assignment starts with a conversation.

Let’s examine
the facts.

For enquiries and assignment requests, please use the contact form.

For urgent matters, please call us directly by phone or WhatsApp.

If your call does not connect, please send a WhatsApp message. Mobile reception may be limited on board vessels or at industrial sites.

Based in Oran, AlgeriaOran · Arzew · Mostaganem · Ghazaouet · Ténès